FVXS25FV1B / RXS25L2V1B FVXS35FV1B / RXS35L2V1B FVXS50FV1B / RXS50L2V1B
Poff (mode arrêt) W 14.0 14.0 15.0
Rafraîchissement Psb (mode veille rafraîchissement) W 14.0 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 2.50 3.50 5.00
    Consommation énergétique annuelle kWh 152 219 297
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.74 5.60 5.89
    Condition D (20 ℃ - 27/19) Pdc kW 1.49 1.50 2.23
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.41 11.01 10.09
    Condition C (25 ℃ - 27/19) Pdc kW 1.41 1.65 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.09 7.94 7.96
    Condition A (35 °C - 27/19) Pdc kW 2.50 3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.12 3.30 3.40
    Condition B (30 ℃ - 27/19) Pdc kW 1.84 2.58 3.69
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.56 5.26 5.29
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 798 1,033 1,546
    Pdesign kW 2.60 2.90 4.20
    Puiss. calor. secours nécess. sous conditions conception kW 0.37 0.50 0.40
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+ A A
    TBivalente Pdh (puiss. calor. déclarée) kW 2.30 2.57 3.72
      Tbiv (température bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.76 2.42 2.21
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 1.08 1.02 1.55
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.98 4.80 4.85
    TOL Tol (limite temp. de fonctionnement) °C -15 -15 -15
      Pdh (puiss. calorifique déclarée) kW 2.09 2.12 3.96
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.31 1.96 1.82
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 2.30 2.57 3.72
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.76 2.42 2.21
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.26 1.19 1.80
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.16 6.35 5.99
    Condition B (2 ℃) Pdh (puiss. calor. déclarée) kW 1.40 1.56 2.27
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.80 4.11 3.98
Puissance frigorifique Nom. Btu/h 8,500 11,900 17,100
  Min. kW 1.3 1.4 1.4
  Nom. Kcal/h 2,150 3,010 4,300
  Max. kW 3.0 3.8 5.6
  Min. Kcal/h 1,120 1,200 1,200
  Min. Btu/h 4,400 4,800 4,800
  Nom. kW 2.5 3.5 5.0
  Max. Btu/h 10,200 13,000 19,100.0
  Max. Kcal/h 2,580 3,270 4,820.0
Pck (mode résistance de carter) W 0.0 0.0 0.0
Efficacité nominale Consommation énergétique annuelle kWh 285 (0.000) 510 (0.000) 775 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A A A
  Nominal efficiency-=-Cop 4.39 3.43 3.23
Chauffage Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Raccords de tuyauterie Liquid DE mm 6.35 6.35 6.35
  Gaz DE mm 9.5 9.5 12.7
  Évacuation DE mm 20.0 20.0 20
  Isolation thermique Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz
Puissance calorifique Min. Btu/h 4,400 4,800 4,800
  Nom. Btu/h 11,600 15,400 19,800
  Max. Kcal/h 3,870 4,300 6,970
  Max. Btu/h 15,400 17,100 27,600
  Nom. kW 3.4 4.5 5.8
  Min. kW 1.3 1.4 1.4
  Nom. Kcal/h 2,920 3,870 4,990
  Min. Kcal/h 1,120 1,200 1,200
  Max. kW 4.5 5.0 8.1
Pto (Thermostat off) W 40.0 40.0 40.0
Puissance absorbée Rafraîchissement Min. kW 0.300 0.300 0.500
    Nom. kW 0.570 1.020 1.550
    Max. kW 0.920 1.250 2.000
  Chauffage Max. kW 1.390 1.880 2.600
    Min. kW 0.290 0.310 0.500
    Nom. kW 0.770 1.190 1.600
Saison froide incluse Oui Oui Oui
Current Courant nominal de fonctionnement - 50 Hz Chauffage A 4.5 (2), 4.3 (3), 4.1 (4) 5.9 (2), 5.6 (3), 5.4 (4) 7.3 (2), 7.0 (3), 6.7 (4)
    Rafraîchissement A 3.5 (2), 3.3 (3), 3.2 (4) 4.9 (2), 4.7 (3), 4.5 (4) 7.2 (2), 6.8 (3), 6.6 (4)
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  220V 220V 220V
  230 V 230 V 230 V
  240V 240V 240V
  Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS, 24 °CBH ; longueur équivalente de tuyauterie : 5m Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS, 24 °CBH ; longueur équivalente de tuyauterie : 5m Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS, 24 °CBH ; longueur équivalente de tuyauterie : 5m
  Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°