FLXS35BAVMB9 / RXS35L2V1B
Poff (mode arrêt) W 14.0
Rafraîchissement Psb (mode veille rafraîchissement) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 3.50
    Consommation énergétique annuelle kWh 252
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.87
    Condition D (20 ℃ - 27/19) Pdc kW 1.42
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.91
    Condition C (25 ℃ - 27/19) Pdc kW 1.66
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.90
    Condition A (35 °C - 27/19) Pdc kW 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 2.88
    Condition B (30 ℃ - 27/19) Pdc kW 2.58
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.59
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 1,068
    Pdesign kW 2.90
    Puiss. calor. secours nécess. sous conditions conception kW 0.45
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalente Pdh (puiss. calor. déclarée) kW 2.57
      Tbiv (température bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.30
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 1.05
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.81
    TOL Tol (limite temp. de fonctionnement) °C -15
      Pdh (puiss. calorifique déclarée) kW 2.25
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.90
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 2.57
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.30
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.23
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.22
    Condition B (2 ℃) Pdh (puiss. calor. déclarée) kW 1.56
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.98
Puissance frigorifique Nom. Btu/h 11,900
  Min. kW 1.2
  Nom. Kcal/h 3,010
  Max. kW 3.8
  Min. Kcal/h 1,030
  Min. Btu/h 4,100
  Nom. kW 3.5
  Max. Btu/h 13,000
  Max. Kcal/h 3,270
Pck (mode résistance de carter) W 0.0
Efficacité nominale Consommation énergétique annuelle kWh 565 (0.000)
  Directive sur l'étiquetage énergétique Chauffage B
  Nominal efficiency-=-Cop 3.10
Chauffage Heating-=-Heating cdh degradation heating 0.25
Raccords de tuyauterie Liquid DE mm 6.35
  Gaz DE mm 9.5
  Évacuation DE mm 18.0
  Isolation thermique Tuyaux de liquide et tuyaux de gaz
Puissance calorifique Min. Btu/h 4,100
  Nom. Btu/h 13,600
  Max. Kcal/h 4,300
  Max. Btu/h 17,100
  Nom. kW 4.0
  Min. kW 1.4
  Nom. Kcal/h 3,440
  Min. Kcal/h 1,030
  Max. kW 5.0
Pto (Thermostat off) W 75.0
Puissance absorbée Rafraîchissement Min. kW 0.300
    Nom. kW 1.130
    Max. kW 1.260
  Chauffage Max. kW 1.850
    Min. kW 0.290
    Nom. kW 1.120
Saison froide incluse Oui
Current Courant nominal de fonctionnement - 50 Hz Chauffage A 5.6 (2), 5.3 (3), 5.1 (4)
    Rafraîchissement A 5.3 (2), 5.1 (3), 4.9 (4)
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  220V
  230 V
  240V
  Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS, 24 °CBH ; longueur équivalente de tuyauterie : 5m
  Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°