FLXS25BAVMB / RXS25K3V1B FLXS25BAVMB / RXS25K2V1B FLXS35BAVMB / RXS35K2V1B FLXS50BAVMB / RXS50K2V1B
Poff (mode arrêt) W 20.0   20.0 20.0
Rafraîchissement Psb (mode veille rafraîchissement) W 20.0   20.0 20.0
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 2.50   3.50 4.90
    Consommation énergétique annuelle kWh 196   273 337
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.46   4.49 5.09
    Condition D (20 ℃ - 27/19) Pdc kW 1.77   1.70 2.11
      puissance absorbée kW       0.21
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.34   8.85 10.04
    Condition C (25 ℃ - 27/19) puissance absorbée kW       0.32
      Pdc kW 1.67   1.66 2.32
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.50   6.83 7.19
    Condition A (35 °C - 27/19) puissance absorbée kW       1.59
      Pdc kW 2.50   3.50 4.90
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.70   2.85 3.08
    Condition B (30 ℃ - 27/19) Pdc kW 1.84   2.58 3.61
      puissance absorbée kW       0.76
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.90   4.54 4.78
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 1,080   1,186 1,708
    Pdesign kW 2.80   2.90 4.50
    Puiss. calor. secours nécess. sous conditions conception kW 0.51   0.55 0.87
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A   A A
    TBivalente Pdh (puiss. calor. déclarée) kW 2.48   2.57 3.98
      Puissance absorbée kW       1.83
      Tbiv (température bivalente) °C -7   -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.16   2.04 2.17
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 1.44   1.39 1.59
      Puissance absorbée kW       0.34
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.84   4.53 4.65
    TOL Tol (limite temp. de fonctionnement) °C -15   -15 -15
      Pdh (puiss. calorifique déclarée) kW 1.98   1.99 3.06
      Puissance absorbée kW       1.71
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.83   1.70 1.79
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 2.48   2.57 3.98
      Puissance absorbée kW       1.83
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.16   2.04 2.17
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.69   1.63 1.86
      Puissance absorbée kW       0.32
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 5.75   5.44 5.82
    Condition B (2 ℃) Puissance absorbée kW       0.62
      Pdh (puiss. calor. déclarée) kW 1.51   1.56 2.42
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.93   3.68 3.90
Puissance frigorifique Nom. Btu/h 8,500 (2) 8,500 (3) 11,900 (2) 16,730 (2)
  Min. kW 1.2 1.2 1.2 0.9
  Nom. Kcal/h 2,150 (2) 2,150 (3) 3,010 (2) 4,210 (2)
  Max. kW 3.0 3.0 3.8 5.3
  Min. Kcal/h 1,030 1,030 1,030 770
  Min. Btu/h 4,100 4,100 4,100 3,070
  Nom. kW 2.5 (2) 2.5 (3) 3.5 (2) 4.9 (2)
  Max. Btu/h 10,200 10,200 13,000 18,090
  Max. Kcal/h 2,580 2,580 3,270 4,560
Pck (mode résistance de carter) W 0.0   0.0 0.0
Efficacité nominale Consommation énergétique annuelle kWh 325 (0.000) 325 (0.000) 565 (0.000) 860 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A A B C
  Nominal efficiency-=-Cop 3.85 3.85 3.10 2.85
Chauffage Heating-=-Heating cdh degradation heating 0.25   0.25 0.25
Raccords de tuyauterie Liquid DE mm 6.35 6.35 6.35 6.35
  Gaz DE mm 9.5 9.5 9.5 12.7
  Évacuation DE mm 18.0 18 18.0 18.0
  Isolation thermique Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz
Puissance calorifique Min. Btu/h 4,100 4,100 4,100 3,070
  Nom. Btu/h 11,600 (3) 11,600 (4) 13,600 (3) 20,830 (3)
  Max. Kcal/h 3,870 3,870 4,300 6,450
  Max. Btu/h 15,400 15,400 17,100 25,610
  Nom. kW 3.4 (3) 3.4 (4) 4.0 (3) 6.1 (3)
  Min. kW 1.2 1.2 1.4 0.9
  Nom. Kcal/h 2,920 (3) 2,920 (4) 3,440 (3) 5,250 (3)
  Min. Kcal/h 1,030 1,030 1,030 770
  Max. kW 4.5 4.5 5.0 7.5
Pto (Thermostat off) W 80.0   80.0 80.0
Puissance absorbée Rafraîchissement Min. kW 0.300 0.300 0.300 0.450
    Nom. kW 0.650 0.650 1.130 1.720
    Max. kW 0.860 0.860 1.260 1.950
  Chauffage Max. kW 1.490 1.490 1.850 3.540
    Min. kW 0.290 0.290 0.290 0.310
    Nom. kW 0.980 0.980 1.230 1.820
Saison froide incluse Oui   Oui Oui
Current Courant nominal de fonctionnement - 50 Hz Chauffage A 4.7 (4), 4.5 (5), 4.3 (6) 4.7 (5), 4.5 (6), 4.3 (7) 5.8 (4), 5.5 (5), 5.3 (6) 8.4 (4), 8.0 (5), 7.7 (6)
    Rafraîchissement A 3.7 (4), 3.6 (5), 3.4 (6) 3.7 (5), 3.6 (6), 3.4 (7) 5.3 (4), 5.1 (5), 4.9 (6) 8.0 (4), 7.6 (5), 7.3 (6)
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Étiquette énergétique : échelle de A (efficacité maximum) à G (efficacité minimum). Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS ; longueur équivalente de tuyauterie : 5m ; dénivelé : 0m Consommation énergétique annuelle : basée sur un fonctionnement moyen de 500 heures par an à pleine charge (conditions nominales) Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS, 24 °CBH ; longueur équivalente de tuyauterie : 5m Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS, 24 °CBH ; longueur équivalente de tuyauterie : 5m
  Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m ; dénivelé : 0m Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS ; longueur équivalente de tuyauterie : 5m ; dénivelé : 0m Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m
  220V Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m ; dénivelé : 0m 220V 220V
  230 V 220V 230 V 230 V
  240V 230 V 240V 240V
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° 240V Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°
    Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°