FHQ35CBVEB / RXS35L3V1B
Poff (mode arrêt) W 14.0
Rafraîchissement Psb (mode veille rafraîchissement) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Eurovent Niveau de puissance sonore - Unité intérieure Rafraîchissement Nom. dBA 53
  Sound power level outdoor Cooling Nom. dBA 61
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 3.40
    Consommation énergétique annuelle kWh 193
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.18
    Condition D (20 ℃ - 27/19) Pdc kW 1.64
      puissance absorbée kW 0.14
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.42
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.18
      Pdc kW 1.61
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.77
    Condition A (35 °C - 27/19) puissance absorbée kW 0.92
      Pdc kW 3.40
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.70
    Condition B (30 ℃ - 27/19) Pdc kW 2.51
      puissance absorbée kW 0.43
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.83
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 981
    Pdh Puissance calorifique à -10° kW 2.63
    Pdesign kW 3.10
    Puiss. calor. secours nécess. sous conditions conception kW 0.47
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+
    TBivalente Pdh (puiss. calor. déclarée) kW 2.74
      Puissance absorbée kW 1.04
      Tbiv (température bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.63
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 1.14
      Puissance absorbée kW 0.20
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.62
    TOL Tol (limite temp. de fonctionnement) °C -15
      Pdh (puiss. calorifique déclarée) kW 2.47
      Puissance absorbée kW 1.12
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.20
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 2.74
      Puissance absorbée kW 1.04
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.63
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.34
      Puissance absorbée kW 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.19
    Condition B (2 ℃) Puissance absorbée kW 0.37
      Pdh (puiss. calor. déclarée) kW 1.67
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.57
Puissance frigorifique Nom. kW 3.4
Pck (mode résistance de carter) W 0.0
Efficacité nominale Consommation énergétique annuelle kWh 459 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A
  Nominal efficiency-=-Cop 3.70 (1)
Chauffage Heating-=-Heating cdh degradation heating 0.25
Puissance calorifique Nom. kW 4.00 (2)
Pto (Thermostat off) W 10.0
Puissance absorbée Rafraîchissement Nom. kW 0.92 (2)
  Chauffage Nom. kW 0.980 (2)
Saison froide incluse Oui
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°