FCQG71FVEB / RZQSG71L2V1B FCQG100FVEB / RZQSG100L7Y1B FCQG100FVEB / RZQSG100L7V1B FCQG100FVEB / RZQSG100L7Y1B9 FCQG125FVEB / RZQSG125L7Y1B FCQG125FVEB / RZQSG125L7V1B FCQG125FVEB / RZQSG125L7Y1B9
Poff (mode arrêt) W 0.0   0.0 0.0   0.0 0.0
Rafraîchissement Psb (mode veille rafraîchissement) W 7.0   7.0 7.0   7.0 7.0
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25 0.25   0.25 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 6.80   9.50 9.50   12.00 12.00
    Consommation énergétique annuelle kWh 466   650.685 650.685   821.918 821.918
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.11 5.11 (6) 5.11 5.11 5.11 (6) 5.11 5.11
    Condition D (20 ℃ - 27/19) Pdc kW 3.63   3.99 3.99   3.98 3.98
      puissance absorbée kW 0.42   0.49 0.48   0.40 0.40
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 8.62   8.10 8.27   10.05 10.04
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.56   0.78 0.77   0.84 0.84
      Pdc kW 3.51   4.56 4.56   5.69 5.69
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.28   5.81 5.90   6.81 6.77
    Condition A (35 °C - 27/19) puissance absorbée kW 2.19   2.88 2.88   4.12 4.12
      Pdc kW 6.80   9.50 9.50   12.00 12.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.10   3.30 3.30   2.91 2.91
    Condition B (30 ℃ - 27/19) Pdc kW 5.01   7.00 7.00   8.84 8.84
      puissance absorbée kW 1.27   1.53 1.59   2.86 2.83
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 3.94   4.58 4.40   3.10 3.12
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 2,327   2,799 2,799   2,949 2,949
    Pdesign kW 6.33   7.60 7.60   8.03 8.03
    Puiss. calor. secours nécess. sous conditions conception kW 0.58   0.53 0.53   0.73 0.69
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A 3.80 (6) A A 3.81 (6) A A
    TBivalente Pdh (puiss. calor. déclarée) kW 5.60   6.72 6.72   7.10 7.10
      Puissance absorbée kW     2.09 2.10   2.41 2.43
      Tbiv (température bivalente) °C -7   -7 -7   -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.25   3.21 3.20   2.94 2.93
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 2.89   3.06 3.05   3.07 3.07
      Puissance absorbée kW     0.56 0.56   0.55 0.56
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.85   5.45 5.50   5.54 5.52
    TOL Tol (limite temp. de fonctionnement) °C -15   -15 -15   -15 -15
      Pdh (puiss. calorifique déclarée) kW 6.00   7.66 7.66   7.64 7.74
      Puissance absorbée kW 3.24   3.70 3.83   3.65 3.69
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.85   2.07 2.03   2.09 2.10
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 5.60   6.72 6.72   7.10 7.10
      Puissance absorbée kW     2.09 2.10   2.41 2.43
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.25   3.21 3.20   2.94 2.93
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 3.28   3.49 3.49   3.50 3.50
      Puissance absorbée kW     0.54 0.54   0.54 0.54
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.73   6.43 6.48   6.53 6.50
    Condition B (2 ℃) Puissance absorbée kW     1.48 1.48   1.46 1.45
      Pdh (puiss. calor. déclarée) kW 4.06   5.07 5.07   5.07 5.07
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.82   3.43 3.41   3.47 3.49
Puissance frigorifique Nom. kW 6.8 9.5 (3) 9.5 9.5 12.0 (3) 12.0 12.0
Pck (mode résistance de carter) W 0.0   0.0 0.0   0.0 0.0
Efficacité nominale Consommation énergétique annuelle kWh 971 (0.000) 1,440 (0.000) 1,440 (0.000) 1,440 (0.000) 1,870 (0.000) 1,870 (0.000) 1,870 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A A A A A A A
  Nominal efficiency-=-Cop 3.21 3.30 3.30 3.30 3.21 3.21 3.21
Chauffage Psb (mode veille chauffage) W     14.0 14.0   14.0 14.0
  Heating-=-Heating cdh degradation heating 0.25   0.25 0.25   0.25 0.25
Puissance calorifique Nom. kW 7.5 10.8 (4) 10.8 10.8 13.5 (4) 13.5 13.5
Pto (Thermostat off) W 34.0   109.0 109.0   97.0 97.0
Puissance absorbée Rafraîchissement Nom. kW   2.88     3.74    
  Chauffage Nom. kW   3.05     3.96    
Saison froide incluse Oui   Oui Oui   Oui Oui
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Consommation énergétique annuelle : basée sur un fonctionnement moyen de 500 heures par an à pleine charge (conditions nominales) Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Consommation énergétique annuelle : basée sur un fonctionnement moyen de 500 heures par an à pleine charge (conditions nominales) Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Étiquette énergétique : échelle de A (efficacité maximum) à G (efficacité minimum). Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Étiquette énergétique : échelle de A (efficacité maximum) à G (efficacité minimum). Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°
    Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. extérieure 35 °CBS ; longueur équivalente de tuyauterie : 5m ; dénivelé : 0m     Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. extérieure 35 °CBS ; longueur équivalente de tuyauterie : 5m ; dénivelé : 0m    
    Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m ; dénivelé : 0m     Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m ; dénivelé : 0m    
    La consommation énergétique annuelle est conforme à la directive 2002/31/CE sur l'étiquetage énergétique.     La consommation énergétique annuelle est conforme à la directive 2002/31/CE sur l'étiquetage énergétique.    
    Les valeurs SEER et SCOP sont conformes à la norme EN 14825.     Les valeurs SEER et SCOP sont conformes à la norme EN 14825.    
    Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°     Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°