FCQG35FVEB / RXS35L3V1B
Poff (mode arrêt) W 14.0
Rafraîchissement Psb (mode veille rafraîchissement) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 3.50
    Consommation énergétique annuelle kWh 193
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.35
    Condition D (20 ℃ - 27/19) Pdc kW 1.53
      puissance absorbée kW 0.13
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.20
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.19
      Pdc kW 1.65
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.84
    Condition A (35 °C - 27/19) puissance absorbée kW 0.94
      Pdc kW 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74
    Condition B (30 ℃ - 27/19) Pdc kW 2.58
      puissance absorbée kW 0.44
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.87
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 949
    Pdesign kW 3.32
    Puiss. calor. secours nécess. sous conditions conception kW 0.72
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A++
    TBivalente Pdh (puiss. calor. déclarée) kW 2.94
      Puissance absorbée kW 1.00
      Tbiv (température bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.93
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 1.15
      Puissance absorbée kW 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.15
    TOL Tol (limite temp. de fonctionnement) °C -15
      Pdh (puiss. calorifique déclarée) kW 2.04
      Puissance absorbée kW 0.83
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.46
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 2.94
      Puissance absorbée kW 1.00
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.93
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.29
      Puissance absorbée kW 0.16
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.97
    Condition B (2 ℃) Puissance absorbée kW 0.35
      Pdh (puiss. calor. déclarée) kW 1.79
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.09
Puissance frigorifique Nom. Btu/h 11,590 (2)
  Min. kW 1.3
  Nom. Kcal/h 2,920 (2)
  Max. kW 4.0
  Min. Kcal/h 1,120
  Min. Btu/h 4,430
  Nom. kW 3.4 (2)
  Max. Btu/h 13,640
  Max. Kcal/h 3,440
Pck (mode résistance de carter) W 0.0
Efficacité nominale Consommation énergétique annuelle kWh 455 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A
  Nominal efficiency-=-Cop 3.74 (1)
Chauffage Heating-=-Heating cdh degradation heating 0.25
Raccords de tuyauterie Liquid DE mm 6.35
  Gaz DE mm 9.5
  Évacuation DE mm VP25 (diamètre ext. : 32 / diamètre int. : 25)
  Isolation thermique Tuyaux de liquide et tuyaux de gaz
Puissance calorifique Min. Btu/h 4,430
  Nom. Btu/h 14,320 (2)
  Max. Kcal/h 4,470
  Max. Btu/h 17,730
  Nom. kW 4.20 (2)
  Min. kW 1.3
  Nom. Kcal/h 3,610 (2)
  Min. Kcal/h 1,120
  Max. kW 5.2
Pto (Thermostat off) W 7.0
Puissance absorbée Rafraîchissement Min. kW 0.400
    Nom. kW 0.909 (2)
    Max. kW 1.100
  Chauffage Max. kW 1.840
    Min. kW 0.230
    Nom. kW 1.200 (2)
Unité intérieure Oui
Current Courant nominal de fonctionnement - 50 Hz Chauffage A 5.40 (3), 5.10 (4), 4.90 (5)
    Rafraîchissement A 4.02 (3), 3.83 (4), 3.64 (5)
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°
  220V
  230 V
  240V