FCQG60FVEB / RXS60F4V1B FCQG60FVEB / RXS60F3V1B
Poff (mode arrêt) W 20.0  
Rafraîchissement Psb (mode veille rafraîchissement) W 20.0  
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 5.70  
    Consommation énergétique annuelle kWh 347  
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.74  
    Condition D (20 ℃ - 27/19) Pdc kW 2.35  
      puissance absorbée kW 0.20  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.44  
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.33  
      Pdc kW 2.69  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.05  
    Condition A (35 °C - 27/19) puissance absorbée kW 1.69  
      Pdc kW 5.70  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.37  
    Condition B (30 ℃ - 27/19) Pdc kW 4.20  
      puissance absorbée kW 0.79  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.34  
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 1,704  
    Pdesign kW 4.71  
    Puiss. calor. secours nécess. sous conditions conception kW 0.94  
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A  
    TBivalente Pdh (puiss. calor. déclarée) kW 4.17  
      Puissance absorbée kW 2.01  
      Tbiv (température bivalente) °C -7  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.07  
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 1.64  
      Puissance absorbée kW 0.33  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.92  
    TOL Tol (limite temp. de fonctionnement) °C -15  
      Pdh (puiss. calorifique déclarée) kW 3.09  
      Puissance absorbée kW 1.88  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.64  
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 4.17  
      Puissance absorbée kW 2.01  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.07  
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.81  
      Puissance absorbée kW 0.29  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.21  
    Condition B (2 ℃) Puissance absorbée kW 0.60  
      Pdh (puiss. calor. déclarée) kW 2.53  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.21  
Puissance frigorifique Nom. kW 5.70 5.70 (3)
Pck (mode résistance de carter) W 0.0  
Efficacité nominale Consommation énergétique annuelle kWh 820 (0.000) 820 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A A
  Nominal efficiency-=-Cop 3.48 3.48
Chauffage Psb (mode veille chauffage) W 20.0  
Raccords de tuyauterie Liquid DE mm 6.35  
  Gaz DE mm 12.7  
  Évacuation DE mm VP20 (diamètre ext. : 26 / diamètre int. : 20)  
  Isolation thermique Tuyaux de liquide et tuyaux de gaz  
Puissance calorifique Nom. kW 7.00 7.00 (4)
Pto (Thermostat off) W 80.0  
Puissance absorbée Rafraîchissement Nom. kW 1.64 1.64
  Chauffage Nom. kW 1.99 1.99
Saison froide incluse Oui  
Current Courant nominal de fonctionnement - 50 Hz Rafraîchissement A 9.6  
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Étiquette énergétique : échelle de A (efficacité maximum) à G (efficacité minimum).
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Consommation énergétique annuelle : basée sur un fonctionnement moyen de 500 heures par an à pleine charge (conditions nominales)
    Rafraîchissement : temp. intérieure  27 °CBS, 19,0 °CBH ; temp. extérieure 35 °CBS ; longueur équivalente de tuyauterie : 5m ; dénivelé : 0m
    Chauffage : temp. intérieure  20 °CBS ; temp. extérieure 7 °CBS, 6 °CBH ; tuyauterie équivalente de réfrigérant : 5m ; dénivelé : 0m
    Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°