FAQ100CVEB9 / RZQG71L9V1B FAQ71CVEB9 / RZQG71L9V1B FAQ100CVEB9 / RZQG100L9V1B
Poff (mode arrêt) W 0.0 0.0 0.0
Rafraîchissement Psb (mode veille rafraîchissement) W 7.0 9.1 9.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Eurovent Niveau de puissance sonore - Unité intérieure Rafraîchissement Nom. dBA 65 61 65
  Sound power level outdoor Cooling Nom. dBA 64 64 66
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 6.80 6.80 9.50
    Consommation énergétique annuelle kWh 366 371 545
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.51 6.43 6.11
    Condition D (20 ℃ - 27/19) Pdc kW 3.97 3.97 5.53
      puissance absorbée kW 0.33 0.33 0.53
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.19 12.19 10.56
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.42 0.42 0.65
      Pdc kW 3.86 3.86 5.40
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.26 9.26 8.31
    Condition A (35 °C - 27/19) puissance absorbée kW 2.00 2.00 2.63
      Pdc kW 6.80 6.80 9.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.40 3.40 3.62
    Condition B (30 ℃ - 27/19) Pdc kW 5.08 5.08 7.00
      puissance absorbée kW 1.18 1.18 1.67
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.33 4.33 4.20
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 2,205 2,205 3,562
    Pdh Puissance calorifique à -10° kW 5.93 5.93 8.8
    Pdesign kW 6.33 6.33 10.20
    Puiss. calor. secours nécess. sous conditions conception kW 0.40 0.40 1.40
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A+ A+
    TBivalente Pdh (puiss. calor. déclarée) kW 5.60 5.60 9.02
      Puissance absorbée kW 2.03 2.03 2.83
      Tbiv (température bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.77 2.77 3.19
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 2.88 2.88 4.02
      Puissance absorbée kW 0.45 0.45 0.67
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.45 6.45 6.07
    TOL Tol (limite temp. de fonctionnement) °C -15 -15 -15
      Pdh (puiss. calorifique déclarée) kW 6.48 6.48 8.43
      Puissance absorbée kW 3.28 3.28 3.77
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.98 1.98 2.24
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 5.60 5.60 9.02
      Puissance absorbée kW 2.03 2.03 2.83
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.77 2.77 3.19
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 3.27 3.27 4.58
      Puissance absorbée kW 0.45 0.45 0.66
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.41 7.41 6.94
    Condition B (2 ℃) Puissance absorbée kW 1.20 1.20 1.75
      Pdh (puiss. calor. déclarée) kW 4.52 4.52 5.96
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.77 3.77 3.41
Puissance frigorifique Nom. kW   6.8 9.5
Pck (mode résistance de carter) W 0.0 0.0 0.0
Efficacité nominale Consommation énergétique annuelle kWh   1,000 (0.000) 1,315 (0.000)
Chauffage Psb (mode veille chauffage) W 7.0 9.1 9.0
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Puissance calorifique Nom. kW   7.5 10.8
Pto (Thermostat off) W 7.0 7.0 9.0
Puissance absorbée Rafraîchissement Nom. kW   2.00 2.63
  Chauffage Nom. kW   2.03 3.00
Saison froide incluse Oui Oui Oui
Remarques Notes-=-Description Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement    
Efficacité nominale Directive sur l'étiquetage énergétique Chauffage   A A
  Nominal efficiency-=-Cop   3.40 3.62
Remarques   La consommation énergétique annuelle est conforme à la directive 2002/31/CE sur l'étiquetage énergétique. Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
    Les valeurs SEER et SCOP sont conformes à la norme EN 14825. Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°