EHVZ04S18CB3V / ERLQ004CAV3 EHVZ08S18CB3V / ERLQ006CAV3 EHVZ08S18CB3V / ERLQ008CAV3 EHVZ16S18CB3V / ERLQ011CAV3 EHVZ16S18CB3V / ERLQ014CAV3 EHVZ16S18CB3V / ERLQ016CAV3
Puissance calorifique Min. kW 1.80 (1) 1.80 (1) 1.80 (1)      
  Nom. kW 4.40 (1), 4.03 (2) 6.00 (1), 5.67 (2) 7.40 (1), 6.89 (2) 11.2 (1), 11.0 (2) 14.4 (1), 13.5 (2) 15.9 (1), 15.1 (2)
  Max. kW 5.12 (1), 4.90 (2) 8.35 (1), 7.95 (2) 10.0 (1), 9.53 (2) 8.60 (3), 8.60 (4) 10.5 (3), 10.7 (4) 11.3 (3), 10.8 (4)
Puissance absorbée Chauffage Nom. kW 0.870 (1), 1.13 (2) 1.27 (1), 1.59 (2) 1.66 (1), 2.01 (2) 2.43 (1), 3.10 (2) 3.39 (1), 4.12 (2) 3.77 (1), 4.67 (2)
    Max. kW       3.13 (3), 4.10 (4) 4.02 (3), 5.21 (4) 4.33 (3), 5.22 (4)
COP 5.04 (1), 3.58 (2) 4.74 (1), 3.56 (2) 4.45 (1), 3.42 (2) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.24 (1), 2.61 (3), 3.28 (2), 2.05 (4) 4.22 (1), 2.61 (3), 3.23 (2), 2.07 (4)
Zone supplémentaire de la pompe Unité à PSE nominale (*RLQ*C*) Chauff. kPa 52.3 (6.000), 55.4 (7.000) 40.6 (6.000), 43.3 (7.000) 28.3 (6.000), 32.7 (7.000) 26.2 (1.000), 28.3 (2.000) 25.0 (5.000) 25.0 (5.000)
Zone principale de la pompe Unité à PSE nominale (*RLQ*C*) Chauff. kPa 48.6 (6.000), 51.9 (7.000) 39.5 (6.000), 42.3 (7.000) 26.4 (6.000), 31.2 (7.000) 18.2 (1.000), 20.7 (2.000) 25.0 (5.000) 25.0 (5.000)
Échangeur de chaleur - côté eau Débit d'eau Chauffage Nom. L/min 12.6 (6), 11.6 (7) 17.2 (6), 16.3 (7) 21.2 (6), 19.8 (7) 32.1 (1), 31.5 (1) 41.3 (1), 38.7 (2) 45.6 (1), 43.3 (2)
Général Coordonnées du fournisseur/fabricant Nom et adresse   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Nom ou marque de commerce   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Description du produit Pompe à chaleur air-eau   Oui Oui Oui Oui Oui Oui
    Pompe à chaleur saumure-eau   non non non non non non
    Système combiné de chauffage pompe à chaleur   Oui Oui Oui Oui Oui Oui
    Pompe à chaleur basse température   non non non non non non
    Réchauffeur supplémentaire intégré   Oui Oui Oui Oui Oui Oui
    Pompe à chaleur eau-eau   non non non non non non
  Niveau de puissance acoustique LW(A) (conformément à la norme EN14825) Intérieur dB(A) 42.0 42.0 42.0 47.0 47.0 47.0
LW(A) - Niveau de puissance sonore (selon EN14825) Unité extérieure dB(A) 61.0 62.0 62.0 64.0 64.0 66.0
Condition sonore Étiquette d'écoconception et énergétique Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825
Tank Name   Réservoir d'eau chaude sanitaire en acier inoxydable, 180 L Réservoir d'eau chaude sanitaire en acier inoxydable, 180 L Réservoir d'eau chaude sanitaire en acier inoxydable, 180 L Réservoir d'eau chaude sanitaire en acier inoxydable, 180 L Réservoir d'eau chaude sanitaire en acier inoxydable, 180 L Réservoir d'eau chaude sanitaire en acier inoxydable, 180 L
Chauffage d'ambiance - général Unité air-eau Débit d'air nominal (unité extérieure) m³/h 2,700 2,820 2,820 5,400 5,400 5,400
  Unité saumure/eau-eau Débit nominal eau/saumure m³/h 0.00 0.00 0.00 0.00 0.00 0.00
  Autre Commande de puissance   Inverter Inverter Inverter Inverter Inverter Inverter
    Cdh (dégradation chauffage)   1.00 1.00 1.00 1.00 1.00 1.00
    Pck (mode résistance de carter) kW 0.00 0.00 0.00 0.055 0.055 0.055
    Poff (mode arrêt) kW 0.0080 0.0080 0.0080 0.055 0.055 0.055
    Psb (mode veille) kW 0.0080 0.0080 0.0080 0.055 0.055 0.055
    Pto (thermostat désactivé) kW 0.0060 0.0070 0.0080 0.057 0.057 0.057
  Dispositif de chauffage supplémentaire intégré Émission de NOx mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00
    Psup kW 3.00 3.00 3.00 3.00 3.00 3.00
    Type d'intrant énergétique   Électrique Électrique Électrique Électrique Électrique Électrique
Chauffage d'eau chaude sanitaire Général Profil de charge déclaré   L L L L L L
    Fonction pour régler le chauffage de l'eau en dehors des heures de pic   Oui Oui Oui Oui Oui Oui
  Climat moyen AEC (consommation électrique annuelle) kWh 1,080 1,190 1,190 1,170 1,170 1,170
    AFC (consommation annuelle de combustible) Gj (2) 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (efficacité en mode ECS) % 95.0 86.4 86.4 87.4 87.4 87.4
    Qelec (consommation électrique quotidienne) kWh 4.93 5.43 5.43 5.32 5.32 5.32
    Qfuel (consommation quotidienne de combustible) kWh 0.00 0.00 0.00 0.00 0.00 0.00
    Classe   A A A A A A
  Climat froid AEC (consommation électrique annuelle) kWh 1,220 1,330 1,330 1,340 1,340 1,340
    AFC (consommation annuelle de combustible) Gj (2) 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (efficacité en mode ECS) % 84.0 77.5 77.5 76.6 76.6 76.6
    Qelec (consommation électrique quotidienne) kWh 5.55 6.05 6.05 6.08 6.08 6.08
    Qfuel (consommation quotidienne de combustible) kWh 0.00 0.00 0.00 0.00 0.00 0.00
  Climat chaud AEC (consommation électrique annuelle) kWh 966 1,120 1,120 1,110 1,110 1,110
    AFC (consommation annuelle de combustible) Gj (2) 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (efficacité du chauffage de l'eau) % 106 91.8 91.8 92.3 92.3 92.3
    Qelec (consommation électrique quotidienne) kWh 4.39 5.10 5.10 5.04 5.04 5.04
    Qfuel (consommation quotidienne de combustible) kWh 0.00 0.00 0.00 0.00 0.00 0.00
Chauffage d'ambiance Sortie d'eau sous climat tempéré : 55 °C Général SCOP   3.20 3.22 3.23 3.09 3.16 3.06
      Cons. énergétique annuelle kWh 2,360 3,370 4,060 6,260 7,900 8,970
      Efficacité saisonnière du chauffage d'ambiance % 125 126 126 120 123 119
      Pnom à -10 °C kW 3.70 5.30 6.40 9.99 12.7 13.9
      Consommation énergétique annuelle Qhe (PCS) Gj (2) 8.48 12.1 14.6 22.6 28.4 32.3
      Classe d'effic. saisonnière du chauffage d'ambiance   A++ A++ A++ A+ A+ A+
    Condition A (-7 °CBS/-8 °CBH) Cdh (dégradation chauffage)   1.00 1.00 1.00 1.00 1.00 1.00
      COPd   2.03 2.02 1.98 1.99 1.76 1.78
      Pdh kW 3.36 4.50 5.47 8.83 9.97 12.2
      PERd % 81.2 80.8 79.2 79.6 70.4 71.2
    Condition B (2 °CBS/1 °CBH) Cdh (dégradation chauffage)   1.00 0.990 1.00 1.00 1.00 1.00
      COPd   3.08 3.17 3.17 3.24 3.55 3.12
      Pdh kW 2.00 4.43 3.43 5.28 6.76 7.61
      PERd % 123 127 127 130 142 125
    Condition C (7 °CBS/6 °CBH) Cdh (dégradation chauffage)   0.990 0.990 0.990 0.950 0.950 1.00
      COPd   4.27 4.20 4.20 4.31 4.22 4.40
      Pdh kW 2.77 3.51 3.50 4.47 4.66 4.83
      PERd % 171 168 168 172 169 176
    Condition D (12 °CBS/11 °CBH) Cdh (dégradation chauffage)   0.990 0.990 0.990 0.930 0.940 0.930
      COPd   6.33 5.82 5.82 6.41 5.44 6.36
      Pdh kW 2.65 3.28 3.28 5.37 5.26 5.38
      PERd % 253 233 233 256 218 254
    Tol (limite de température de fonctionnement) COPd   1.80 1.74 1.66 1.79 1.75 1.71
      Pdh kW 3.76 4.62 6.18 9.08 12.2 13.3
      PERd % 72.0 69.6 66.4 71.6 70.0 68.4
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      WTOL °C 55.0 55.0 55.0 55.0 55.0 55.0
    Cap. suppl. puiss. calorif. nom. Psup (à Tconception -10 °C) kW 0.00 0.680 0.220 0.910 0.550 0.580
    Tbiv (température bivalente) COPd   1.80 1.74 1.66 1.99 1.92 1.78
      Pdh kW 3.76 5.09 6.18 8.83 11.0 12.2
      PERd % 72.0 69.6 66.4 79.6 76.8 71.2
      Tbiv °C -10.0 -9.00 -10.0 -7.00 -6.00 -7.00
  Sortie d'eau climat froid : 55 °C Général Consommation énergétique annuelle kWh 2,130 2,310 3,090 6,740 7,870 8,580
      Efficacité saisonnière du chauffage d'ambiance % 107 107 110 95.0 95.5 98.3
      Pnom à -22°C kW 2.39 2.60 3.56 6.99 8.15 9.12
      Consommation énergétique annuelle Qhe (PCS) Gj (2) 7.68 8.30 11.1 24.3 28.3 30.9
  Climat chaud - sortie d'eau à 55 °C Général Cons. énergétique annuelle kWh 1,170 1,490 1,900 2,630 3,270 3,420
      Ƞs (effic. saisonnière du chauffage d'ambiance) % 186 182 178 125 135 136
      Pnom à 2°C kW 4.27 5.30 6.59 7.58 9.84 10.3
      Consommation énergétique annuelle Qhe (PCS) Gj (2) 4.20 5.37 6.85 9.47 11.8 12.3
  Sortie d'eau climat tempéré 35 °C Général SCOP   4.52 4.29 4.34      
      Cons. énergétique annuelle kWh 1,980 2,540 3,490      
      Ƞs (effic. saisonnière du chauffage d'ambiance) % 178 169 171      
      Pnominal à -10 °C kW 4.40 5.34 7.40      
      Consommation énerg. annuelle Qhe (GCV) Gj (2) 7.13 9.14 12.6      
      Classe d'eff. saisonnière du chauffage d'ambiance   A++ A++ A++      
    Condition A(-7°CBS/-8°CBH) COPd   3.01 2.69 2.69      
      Pdh kW 4.01 4.72 6.68      
      PERd % 120 108 108      
    Condition B (2° CBS/1° CBH) Cdh (dégradation chauffage)   1.00 0.990 1.00      
      COPd   4.41 4.24 4.24      
      Pdh kW 2.40 3.90 3.90      
      PERd % 176 170 170      
    Condition C (7 °CBS/6 °CBH) Cdh (dégradation chauffage)   0.980 0.980 1.00      
      COPd   5.85 5.75 5.75      
      Pdh kW 1.70 2.59 2.59      
      PERd % 234 230 230      
    Condition D (12 °CBS/11 °CBH) Cdh (dégradation chauffage)   0.980 0.980 0.980      
      COPd   7.71 7.27 7.27      
      Pdh kW 2.04 2.61 2.61      
      PERd % 308 291 291      
    Tol (limite de température de fonctionnement) COPd   2.61 2.29 2.29      
      Pdh kW 4.36 4.70 6.81      
      PERd % 104 91.6 91.6      
      TOL °C -10.0 -10.0 -10.0      
      WTOL °C 35.0 35.0 35.0      
    Tbiv (température bivalente) COPd   2.61 2.47 2.47      
      Pdh kW 4.36 4.93 7.14      
      PERd % 104 98.8 98.8      
      Tbiv °C -10.0 -8.00 -8.00      
    Sortie calorifique nom. - Puiss. suppl. Psup (à Tconception -10 °C) kW 0.040 0.640 0.590      
Remarques Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C)
  Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C)
  Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C
  Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C
  La capacité doit être répartie entre zone principale et zone supplémentaire. Se reporter aux données de PSE pour plus de détails sur la hauteur disponible (kPa). La capacité doit être répartie entre zone principale et zone supplémentaire. Se reporter aux données de PSE pour plus de détails sur la hauteur disponible (kPa). La capacité doit être répartie entre zone principale et zone supplémentaire. Se reporter aux données de PSE pour plus de détails sur la hauteur disponible (kPa). La capacité doit être répartie entre zone principale et zone supplémentaire. Se reporter aux données de PSE pour plus de détails sur la hauteur disponible (kPa). La capacité doit être répartie entre zone principale et zone supplémentaire. Se reporter aux données de PSE pour plus de détails sur la hauteur disponible (kPa). La capacité doit être répartie entre zone principale et zone supplémentaire. Se reporter aux données de PSE pour plus de détails sur la hauteur disponible (kPa).
  BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C)
  BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C)