EHVH16S26CA9W / ERLQ011CAW1 EHVH16S18CA3V / ERLQ011CAW1 EHVH16S26CA9W / ERLQ014CAW1 EHVH16S18CA3V / ERLQ014CAW1 EHVH16S26CA9W / ERLQ016CAW1 EHVH16S18CA3V / ERLQ016CAW1
Puissance calorifique Nom. kW 11.2 (1), 11.00 (2) 11.2 (1), 11.00 (2) 14.5 (1), 13.60 (2) 14.5 (1), 13.60 (2) 16 (1), 15.20 (2) 16 (1), 15.20 (2)
  Max. kW 8.6 (3), 8.60 (4) 8.6 (3), 8.60 (4) 10.6 (3), 10.80 (4) 10.6 (3), 10.80 (4) 11.4 (3), 10.90 (4) 11.4 (3), 10.90 (4)
Puissance absorbée Chauffage Max. kW 3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
    Nom. kW 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
Cop 4.6 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.6 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.3 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.3 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4)
Remarques Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C)
  Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C)
  Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C
  Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C