EHSXB04P30DA / ERGA04DAV3 EHSXB04P50DA / ERGA04DAV3 EHSXB08P30DA / ERGA06DAV3 EHSXB08P50DA / ERGA06DAV3 EHSXB08P50DA / ERGA08DAV3 EHSXB08P30DA / ERGA08DAV3
Unité intérieure EHSXB04P30D EHSXB04P50D EHSXB08P30D EHSXB08P50D EHSXB08P50D EHSXB08P30D
Unité extérieure ERGA04DAV3 RRGA04DAV3 ERGA06DAV3 ERGA06DAV3 ERGA08DAV3 ERGA08DAV3
Puissance calorifique Nom. kW 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Puissance frigorifique Nom. kW 5.56 (1), 4.37 (2) 5.56 (1), 4.37 (2) 5.96 (1), 4.87 (2) 5.96 (1), 4.87 (2) 6.25 (1), 5.35 (2) 6.25 (1), 5.35 (2)
Puissance absorbée Chauffage Nom. kW 0.850 (1), 1.26 (2) 0.850 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
  Rafraîchissement Nom. kW 0.940 (1), 1.14 (2) 0.940 (1), 1.14 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.33 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2)
Heat up time from 10°C to 50°C hr 1h31min 2h38min 1h31min 2h38min 2h38min 1h31min
COP 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
EER 5.94 (1), 3.84 (2) 5.94 (1), 3.84 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.67 (2) 5.40 (1), 3.54 (2) 5.40 (1), 3.54 (2)
Pompe Type   Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL
  Unité à PSE nominale Rafraîchissement kPa 60.5 (1), 65.8 (2) 60.5 (1), 65.8 (2) 57.6 (1), 63.9 (2) 57.6 (1), 63.9 (2) 55.5 (1), 61.7 (2) 55.5 (1), 61.7 (2)
    Chauffage kPa 66.0 (1), 65.0 (2) 66.0 (1), 65.0 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 42.7 (1), 38.7 (2) 42.7 (1), 38.7 (2)
Échangeur de chaleur - côté eau Débit d'eau Rafraîchissement Nom. L/min 15.9 (1), 12.5 (2) 15.9 (1), 12.5 (2) 17.1 (1), 14.0 (2) 17.1 (1), 14.0 (2) 17.9 (1), 15.3 (2) 17.9 (1), 15.3 (2)
    Chauffage Nom. L/min 12.3 (1), 13.2 (2) 12.3 (1), 13.2 (2) 17.2 (1), 16.9 (2) 17.2 (1), 16.9 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2)
Général Description du produit Pompe à chaleur air-eau   Oui Oui Oui Oui Oui Oui
    Pompe à chaleur saumure-eau   non non non non non non
    Système combiné de chauffage pompe à chaleur   Oui Oui Oui Oui Oui Oui
    Pompe à chaleur basse température   non non non non non non
    Réchauffeur supplémentaire intégré   non non non non non non
    Pompe à chaleur eau-eau   non non non non non non
  Niveau de puissance acoustique LW(A) (conformément à la norme EN14825) Intérieur dB(A) 39 39 39 39 39 39
LW(A) - Niveau de puissance sonore (selon EN14825) Unité extérieure dB(A) 58 58 60 60 62 62
Condition sonore Étiquette d'écoconception et énergétique Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825 Puissance sonore en mode chauffage mesurée conformément à la norme EN12102 dans les conditions de la norme EN14825
Chauffage d'ambiance - général Unité air-eau Débit d'air nominal (unité extérieure) m³/h 2,280 2,280 2,520 2,520 2,770 2,770
  Autre Commande de puissance   Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (mode arrêt) kW 0.010 0.010 0.010 0.010 0.010 0.010
    Psb (mode veille) kW 0.010 0.010 0.010 0.010 0.010 0.010
    Pto (thermostat désactivé) kW 0.010 0.010 0.010 0.010 0.010 0.010
  Dispositif de chauffage supplémentaire intégré Type d'intrant énergétique   Électrique Électrique Électrique Électrique Électrique Électrique
Chauffage d'eau chaude sanitaire Général Profil de charge déclaré   L XL L XL XL L
    Fonction pour régler le chauffage de l'eau en dehors des heures de pic   Oui Oui Oui Oui Oui Oui
  Climat moyen AEC (consommation électrique annuelle) kWh 951 1,541 951 1,541 1,541 951
    Ƞwh (efficacité en mode ECS) % 108 109 108 109 109 108
    Qelec (consommation électrique quotidienne) kWh 4.500 7.251 4.500 7.251 7.251 4.500
    Classe   A A A A A A
  Climat froid AEC (consommation électrique annuelle) kWh 1,366 1,852 1,366 1,852 1,852 1,366
    Ƞwh (efficacité en mode ECS) % 75 90 75 90 90 75
    Qelec (consommation électrique quotidienne) kWh 6.454 8.665 6.454 8.665 8.665 6.454
  Climat chaud AEC (consommation électrique annuelle) kWh 940 1,343 940 1,343 1,343 940
    Ƞwh (efficacité du chauffage de l'eau) % 109 125 109 125 125 109
    Qelec (consommation électrique quotidienne) kWh 4.513 6.346 4.513 6.346 6.346 4.513
Chauffage d'ambiance Sortie d'eau sous climat tempéré : 55 °C Général SCOP   3.26 3.26 3.26 3.26 3.32 3.32
      Cons. énergétique annuelle kWh 3,806 3,806 4,441 4,441 4,975 4,975
      Efficacité saisonnière du chauffage d'ambiance % 127 127 127 127 130 130
      Pnom à -10 °C kW 6.0 6.0 7.0 7.0 8.0 8.0
      Classe d'effic. saisonnière du chauffage d'ambiance   A++ A++ A++ A++ A++ A++
    Condition A (-7 °CBS/-8 °CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   1.97 1.97 1.98 1.98 1.96 1.96
      Pdh kW 5.3 5.3 5.9 5.9 6.9 6.9
      PERd % 79.0 79.0 79.0 79.0 78.0 78.0
    Condition B (2 °CBS/1 °CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.23 3.23 3.16 3.16 3.20 3.20
      Pdh kW 3.3 3.3 3.9 3.9 4.4 4.4
      PERd % 129.0 129.0 126.0 126.0 128.0 128.0
    Condition C (7 °CBS/6 °CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.40 4.40 4.49 4.49 4.64 4.64
      Pdh kW 3.0 3.0 3.0 3.0 3.3 3.3
      PERd % 176.0 176.0 180.0 180.0 186.0 186.0
    Condition D (12 °CBS/11 °CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.22 6.22
      Pdh kW 3.3 3.3 3.3 3.3 4.1 4.1
      PERd % 244.0 244.0 244.0 244.0 249.0 249.0
    Tol (limite de température de fonctionnement) COPd   1.37 1.37 1.53 1.53 1.64 1.64
      Pdh kW 4.0 4.0 5.4 5.4 7.1 7.1
      PERd % 55.0 55.0 61.0 61.0 66.0 66.0
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Tbiv (température bivalente) COPd   1.97 1.97 2.12 2.12 1.90 1.90
      Pdh kW 5.3 5.3 6.1 6.1 7.5 7.5
      PERd % 79.0 79.0 85.0 85.0 76.0 76.0
      Tbiv °C -7 -7 -6 -6 -8 -8
  Sortie d'eau climat froid : 55 °C Général Consommation énergétique annuelle kWh 4,468 4,468 5,300 5,300 6,886 6,886
      Efficacité saisonnière du chauffage d'ambiance % 107 107 109 109 112 112
      Pnom à -22°C kW 5 5 6 6 8 8
  Climat chaud - sortie d'eau à 55 °C Général Cons. énergétique annuelle kWh 1,660 1,660 1,858 1,858 2,213 2,213
      Ƞs (effic. saisonnière du chauffage d'ambiance) % 148 148 158 158 161 161
      Pnom à 2°C kW 5 5 6 6 7 7
  Sortie d'eau climat tempéré 35 °C Général SCOP   4.48 4.48 4.47 4.47 4.56 4.56
      Cons. énergétique annuelle kWh 2,766 2,766 3,233 3,233 3,625 3,625
      Ƞs (effic. saisonnière du chauffage d'ambiance) % 176 176 176 176 179 179
      Pnominal à -10 °C kW 6.0 6.0 7.0 7.0 8.0 8.0
      Consommation énerg. annuelle Qhe (GCV) Gj (2) 1 1 1 1 1 1
      Classe d'eff. saisonnière du chauffage d'ambiance   A++ A++ A++ A++ A++ A++
    Condition A(-7°CBS/-8°CBH) COPd   2.90 2.90 2.86 2.86 2.77 2.77
      Pdh kW 5.5 5.5 6.0 6.0 7.0 7.0
      PERd % 116.0 116.0 114.0 114.0 111.0 111.0
    Condition B (2° CBS/1° CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.33 4.33 4.25 4.25 4.35 4.35
      Pdh kW 3.3 3.3 3.9 3.9 4.2 4.2
      PERd % 173.0 173.0 170.0 170.0 174.0 174.0
    Condition C (7 °CBS/6 °CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.19 6.19 6.30 6.30 6.49 6.49
      Pdh kW 3.2 3.2 3.2 3.2 3.3 3.3
      PERd % 248.0 248.0 252.0 252.0 260.0 260.0
    Condition D (12 °CBS/11 °CBH) Cdh (dégradation chauffage)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.78 7.78 7.78 7.78 8.52 8.52
      Pdh kW 3.3 3.3 3.3 3.3 3.9 3.9
      PERd % 311.0 311.0 311.0 311.0 341.0 341.0
    Tol (limite de température de fonctionnement) COPd   2.56 2.56 2.49 2.49 2.41 2.41
      Pdh kW 5.2 5.2 6.0 6.0 6.9 6.9
      PERd % 102.0 102.0 100.0 100.0 96.0 96.0
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (température bivalente) COPd   2.90 2.90 2.49 2.49 2.66 2.66
      Pdh kW 5.5 5.5 6.0 6.0 7.5 7.5
      PERd % 116.0 116.0 100.0 100.0 106.0 106.0
      Tbiv °C -7 -7 -6 -6 -8 -8
    Sortie calorifique nom. - Puiss. suppl. Psup (à Tconception -10 °C) kW 0.8 0.8        
  Sortie d'eau climat froid 35 °C Général Consommation énergétique annuelle kWh 3,230 3,230 3,749 3,749 5,034 5,034
      Ƞs (efficacité saisonnière du chauffage d'ambiance) % 150 150 155 155 154 154
      Pnom à -22°C kW 5 5 6 6 8 8
  Sortie d'eau en conditions climatiques chaudes 35 °C Général Cons. énergétique annuelle kWh 1,139 1,139 1,276 1,276 1,437 1,437
      Ƞs (effic. saisonnière du chauffage d'ambiance) % 241 241 248 248 257 257
      Pnom à 2°C kW 5 5 6 6 7 7
Remarques Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C)
  Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C)