Tableau avec les données techniques pour EHBX-C / ERLQ-CW1

EHBX16CA3V / ERLQ011CAW1 EHBX16CA9W / ERLQ011CAW1 EHBX16CA9W / ERLQ014CAW1 EHBX16CA3V / ERLQ014CAW1 EHBX16CA9W / ERLQ016CAW1 EHBX16CA3V / ERLQ016CAW1
Puissance calorifique Nom. kW 11.2 (1), 11.00 (2) 11.2 (1), 11.00 (2) 14.5 (1), 13.60 (2) 14.5 (1), 13.60 (2) 16 (1), 15.20 (2) 16 (1), 15.20 (2)
  Max. kW 8.6 (3), 8.60 (4) 8.6 (3), 8.60 (4) 10.6 (3), 10.80 (4) 10.6 (3), 10.80 (4) 11.4 (3), 10.90 (4) 11.4 (3), 10.90 (4)
Puissance frigorifique Nom. kW 15.05 (1), 11.72 (2) 15.05 (1), 11.72 (2) 16.06 (1), 12.55 (2) 16.06 (1), 12.55 (2) 16.76 (1), 13.12 (2) 16.76 (1), 13.12 (2)
Puissance absorbée Chauffage Nom. kW 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
    Max. kW 3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
  Rafraîchissement Nom. kW 4.53 (1), 4.31 (2) 4.53 (1), 4.31 (2) 5.43 (1), 5.08 (2) 5.43 (1), 5.08 (2) 6.16 (1), 5.73 (2) 6.16 (1), 5.73 (2)
COP 4.6 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.6 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.3 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.3 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4)
EER 3.32 (1), 2.72 (2) 3.32 (1), 2.72 (2) 2.96 (1), 2.47 (2) 2.96 (1), 2.47 (2) 2.72 (1), 2.29 (2) 2.72 (1), 2.29 (2)
Remarques (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C)
  (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C)
  (3) - Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C (3) - Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C (3) - Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C (3) - Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C (3) - Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C (3) - Condition 3 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 35 °C
  (4) - Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C (4) - Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C (4) - Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C (4) - Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C (4) - Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C (4) - Condition 4 : chauffage Ta BS -7 °C (HR : 85 %) - LWC 45 °C