ATXM25M2V1B / ARXM25M2V1B ATXM35M2V1B / ARXM35M2V1B ATXM50M2V1B / ARXM50MV1B
Poff (mode arrêt) W 1.0 1.0 1.0
Rafraîchissement Psb (mode veille rafraîchissement) W 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Eurovent Niveau de puissance sonore - Unité intérieure Rafraîchissement Nom. dBA 58 60 59
  Sound power level outdoor Cooling Nom. dBA 59 61 62
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 2.50 3.40 5.00
    Consommation énergétique annuelle kWh 103 140 239
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy label 8.50 8.50 7.31
    Condition D (20 ℃ - 27/19) Pdc kW 0.96 1.18 2.12
      puissance absorbée kW 0.07 0.07 0.15
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 14.78 16.57 14.51
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.11 0.16 0.29
      Pdc kW 1.18 1.61 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 10.70 10.32 8.27
    Condition A (35 °C - 27/19) puissance absorbée kW 0.57 0.83 1.45
      Pdc kW 2.50 3.40 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.39 4.09 3.45
    Condition B (30 ℃ - 27/19) Pdc kW 1.84 2.51 3.68
      puissance absorbée kW 0.29 0.41 0.66
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.42 6.11 5.55
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 659 686 1,400
    Pdesign kW 2.40 2.50 4.60
    Puiss. calor. secours nécess. sous conditions conception kW 0.10 0.15 0.51
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+++ A+++ A++
    TBivalente Pdh (puiss. calor. déclarée) kW 2.12 2.21 4.07
      Puissance absorbée kW 0.60 0.63 1.40
      Tbiv (température bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.51 3.50 2.90
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 0.91 0.95 1.61
      Puissance absorbée kW 0.14 0.15 0.28
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.32 6.43 5.83
    TOL Tol (limite temp. de fonctionnement) °C -15 -15 -15
      Pdh (puiss. calorifique déclarée) kW 2.59 2.59 4.12
      Puissance absorbée kW 1.04 1.04 1.91
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.49 2.49 2.16
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 2.12 2.21 4.07
      Puissance absorbée kW 0.60 0.63 1.40
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.51 3.50 2.90
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.09 1.09 1.36
      Puissance absorbée kW 0.14 0.14 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 8.03 8.05 7.07
    Condition B (2 ℃) Puissance absorbée kW 0.25 0.27 0.53
      Pdh (puiss. calor. déclarée) kW 1.29 1.34 2.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.06 5.03 4.65
  Chauffage (climat chaud) Puiss. calor. secours nécess. sous conditions de conception kW 0.00 0.00 0.00
    Consommation énergétique annuelle kWh 275 289 556
    Pdesign kW 1.19 1.27 2.30
    Seasonal efficiency (according to EN14825)-=-Heating (Warm climate)-=-Seasonal efficiency according to en14825 heating warm climate energy label 6.06 6.16 5.79
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.1 1.1 1.4
      Puissance absorbée kW 0.14 0.14 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Warm climate)-=-D Condition (12°C)-=-Copd declared cop 8.03 8.05 7.07
    TBivalente Tbiv (température bivalente) °C 2 2 2
      Pdh (puiss. calor. déclarée) kW 1.19 1.27 2.30
      Puissance absorbée kW 0.24 0.26 0.50
      Seasonal efficiency (according to EN14825)-=-Heating (Warm climate)-=-TBivalent-=-Copd declared cop 5.01 4.98 4.59
    TOL Pdh (puissance calorifique déclarée) kW 2.59 2.59 4.12
      Puissance absorbée kW 1.04 1.04 1.91
      Tol (limite temp. de fonctionnement) °C -15 -15 -15
      Seasonal efficiency (according to EN14825)-=-Heating (Warm climate)-=-TOL-=-Copd declared cop 2.49 2.49 2.16
    Condition B (2 ℃) Pdh (puiss. calor. déclarée) kW 1.19 1.27 2.30
      Puissance absorbée kW 0.24 0.26 0.50
      Seasonal efficiency (according to EN14825)-=-Heating (Warm climate)-=-B Condition (2°C)-=-Copd declared cop 5.01 4.98 4.59
    Condition C (7 ℃) Puissance absorbée kW 0.14 0.15 0.28
      Pdh (puiss. calor. déclarée) kW 0.91 0.95 1.61
      Seasonal efficiency (according to EN14825)-=-Heating (Warm climate)-=-C Condition (7°C)-=-Copd declared cop 6.32 6.43 5.83
Puissance frigorifique Nom. Btu/h 8,500 11,600 17,100
  Min. kW 1.3 1.4 1.7
  Nom. Kcal/h 2,150 2,920 4,300
  Max. kW 3.2 4.0 5.3
  Min. Kcal/h 1,120 1,200 1,460
  Min. Btu/h 4,400 4,800 5,800
  Nom. kW 2.5 3.40 5.02
  Max. Btu/h 11,000 13,600 18,100
  Max. Kcal/h 2,750 3,440 4,560
Efficacité nominale Consommation énergétique annuelle kWh 285 416 728
  Directive sur l'étiquetage énergétique Chauffage A A A
  Nominal efficiency-=-Cop 4.39 4.09 3.45
Chauffage Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Puissance calorifique Min. Btu/h 4,400 4,800 5,800
  Nom. Btu/h 9,500 13,600 19,800
  Max. Kcal/h 4,040 4,470 5,590
  Max. Btu/h 1,600 17,700 22,200
  Nom. kW 2.8 4.00 5.8
  Min. kW 1.3 1.4 1.7
  Nom. Kcal/h 2,400 3,440 4,990
  Min. Kcal/h 1,120 1,200 1,460
  Max. kW 4.7 5.2 6.5
Pto (Thermostat off) W 12.0 12.0 12.0
Puissance absorbée Rafraîchissement Min. kW 0.28 0.32  
    Nom. kW 0.57 0.83 1.46
    Max. kW 0.80 1.08  
  Chauffage Max. kW 1.22 1.67  
    Min. kW 0.24 0.32  
    Nom. kW 0.56 0.99 1.53
Unité intérieure Oui Oui Oui
Current Courant nominal de fonctionnement - 50 Hz Chauffage A 2.48 4.78 6.95
    Rafraîchissement A 2.64 4.52 6.74
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°