Tableau avec les données techniques pour ATX-KV / ARX-K

ATX20K2V1B / ARX20K2V1B ATX25K2V1B / ARX25K2V1B ATX35K2V1B / ARX35K2V1B
Poff (mode arrêt) W 1.0 1.0 1.0
Rafraîchissement Psb (mode veille rafraîchissement) W 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 2.00 2.50 3.50
    Consommation énergétique annuelle kWh 106 135 191
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.62 6.46 6.42
    Condition D (20 ℃ - 27/19) Pdc kW 1.32 1.32 1.35
      puissance absorbée kW 0.14 0.14 0.14
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.68 9.57 9.57
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.14 0.14 0.20
      Pdc kW 1.22 1.22 1.56
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.56 8.46 8.00
    Condition A (35 °C - 27/19) puissance absorbée kW 0.50 0.66 1.02
      Pdc kW 2.00 2.50 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.97 3.78 3.43
    Condition B (30 ℃ - 27/19) Pdc kW 1.47 1.84 2.43
      puissance absorbée kW 0.23 0.36 0.47
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.26 5.13 5.20
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 664 730 849
    Pdh Puissance calorifique à -10° kW 1.74 1.85 2.17
    Pdesign kW 2.20 2.40 2.80
    Puiss. calor. secours nécess. sous conditions conception kW 0.46 0.55 0.63
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A++ A++ A++
    TBivalente Pdh (puiss. calor. déclarée) kW 1.95 2.12 2.48
      Puissance absorbée kW 0.67 0.75 0.93
      Tbiv (température bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.90 2.84 2.67
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 0.92 0.92 1.00
      Puissance absorbée kW 0.15 0.15 0.16
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.10 6.13 6.11
    TOL Tol (limite temp. de fonctionnement) °C -15 -15 -15
      Pdh (puiss. calorifique déclarée) kW 1.40 1.40 1.65
      Puissance absorbée kW 0.77 0.77 0.87
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.82 1.82 1.90
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 1.95 2.12 2.48
      Puissance absorbée kW 0.67 0.75 0.93
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.92 2.84 2.67
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.02 1.02 1.10
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.08 7.12 7.10
    Condition B (2 ℃) Puissance absorbée kW 0.24 0.27 0.31
      Pdh (puiss. calor. déclarée) kW 1.18 1.29 1.50
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.83 4.74 4.82
Puissance frigorifique Nom. kW 2.0 (2) 2.5 (2) 3.5 (2)
Pck (mode résistance de carter) W 0.0 0.0 0.0
Efficacité nominale Annual energy consumption kWh 252 (0.000) 331 (0.000) 510 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A A A
  Nominal efficiency-=-Cop 3.97 (1) 3.78 (1) 3.43 (1)
Chauffage Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Raccords de tuyauterie Liquid DE mm 6.35 6.35 6.35
  Gaz DE mm 9.5 9.5 9.5
  Évacuation DE mm 18 18 18
  Isolation thermique Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz
Puissance calorifique Nom. kW 2.5 (2) 3.0 (2) 4.0 (2)
Pto (Thermostat off) W 21.0 21.0 21.0
Puissance absorbée Chauffage Nom. kW 0.524 (2) 0.688 (2) 0.995 (2)
Saison froide incluse Oui Oui Oui
Courant Courant nominal de fonctionnement - 50 Hz Chauffage A 2.67 3.50 5.03
    Rafraîchissement A 2.47 3.25 5.42
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°