ABQ71CV1 / AZQS71B2V1B UK ABQ100CV1 / AZQS100B8V1B UK ABQ125CV1 / AZQS125B8V1B UK ABQ140CV1 / AZQS140B8V1B UK
Poff (mode arrêt) W 0.0 9.0    
Rafraîchissement Psb (mode veille rafraîchissement) W 9.0 9.0    
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25    
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Pdesign kW 6.80 9.50    
    Consommation énergétique annuelle kWh 512 716    
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.65 4.65    
    Condition D (20 ℃ - 27/19) Pdc kW 3.90 4.20    
      puissance absorbée kW   0.58    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 7.22 7.35    
    Condition C (25 ℃ - 27/19) puissance absorbée kW   0.76    
      Pdc kW 3.80 4.50    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.23 5.94    
    Condition A (35 °C - 27/19) puissance absorbée kW   3.63    
      Pdc kW 6.80 9.50    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 2.91 2.62    
    Condition B (30 ℃ - 27/19) Pdc kW 5.01 7.00    
      puissance absorbée kW   1.86    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.22 3.78    
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 2,082 2,499    
    Pdesign kW 5.65 6.78    
    Puiss. calor. secours nécess. sous conditions conception kW 0.35 0.15    
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A A    
    TBivalente Pdh (puiss. calor. déclarée) kW 5.00 6.00    
      Puissance absorbée kW   2.20    
      Tbiv (température bivalente) °C -7 -7    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.74 2.73    
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 2.90 3.00    
      Puissance absorbée kW   0.56    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.34 5.43    
    TOL Tol (limite temp. de fonctionnement) °C -15 -15    
      Pdh (puiss. calorifique déclarée) kW 5.80 7.70    
      Puissance absorbée kW   4.33    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.06 1.78    
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 5.00 6.00    
      Puissance absorbée kW   2.20    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.74 2.73    
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 3.30 3.50    
      Puissance absorbée kW   0.55    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.19 6.45    
    Condition B (2 ℃) Puissance absorbée kW   1.05    
      Pdh (puiss. calor. déclarée) kW 3.00 3.70    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.68 3.55    
Puissance frigorifique Nom. kW 6.8 9.5 12.1 13.0
Pck (mode résistance de carter) W 0.0 0.0    
Efficacité nominale Consommation énergétique annuelle kWh 1,165 (0.000) 1,813 (0.000) 2,153 (0.000) 2,159 (0.000)
  Directive sur l'étiquetage énergétique Chauffage C D C C
  Nominal efficiency-=-Cop 2.91 2.62 2.81 3.01
Chauffage Psb (mode veille chauffage) W   9.0    
  Heating-=-Heating cdh degradation heating 0.25 0.25    
Puissance calorifique Nom. kW 7.5 10.8 13.5 15.5
Pto (Thermostat off) W 128.0 109.0    
Puissance absorbée Rafraîchissement Nom. kW 2.33 3.63 4.31 4.32
  Chauffage Nom. kW 2.13 3.16 3.96 4.55
Unité intérieure Oui Oui AZQS125B8V1 UK AZQS140B8V1 UK
Remarques La consommation énergétique annuelle est conforme à la directive 2002/31/CE sur l'étiquetage énergétique. Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Les valeurs SEER et SCOP sont conformes à la norme EN 14825. Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° DESP : montage = catégorie l : hors du champ d'application DESP en raison de l'article 1, élément 3.6 de la directive 97/23/CE DESP : montage = catégorie l : hors du champ d'application DESP en raison de l'article 1, élément 3.6 de la directive 97/23/CE DESP : montage = catégorie l : hors du champ d'application DESP en raison de l'article 1, élément 3.6 de la directive 97/23/CE
    Valeur Ssc (=puissance de court-circuit) minimum : Équipement conforme à la norme EN 61000-3-2 Valeur Ssc (=puissance de court-circuit) minimum : Équipement conforme à la norme EN 61000-3-2 Valeur Ssc (=puissance de court-circuit) minimum : Équipement conforme à la norme EN 61000-3-2
    Pour les données électriques, se reporter au schéma séparé. Pour les données électriques, se reporter au schéma séparé. Pour les données électriques, se reporter au schéma séparé.
    Contient des gaz à effet de serre fluorés. Contient des gaz à effet de serre fluorés. Contient des gaz à effet de serre fluorés.