| ETSHB16P30EF7 / EPRA14DAW17 | ETSHB16P50EF7 / EPRA14DAW17 | ETSHB16P30EF7 / EPRA14DBW17 | ETSHB16P50EF7 / EPRA14DBW17 | ETSHB16P30EG7 / EPRA14DAW17 | ETSHB16P30EG7 / EPRA14DBW17 | ETSHB16P50EG7 / EPRA14DAW17 | ETSHB16P50EG7 / EPRA14DBW17 | ETSHB16P50EF7 / EPRA16DAW17 | ETSHB16P30EF7 / EPRA16DAW17 | ETSHB16P30EF7 / EPRA16DBW17 | ETSHB16P50EF7 / EPRA16DBW17 | ETSHB16P30EG7 / EPRA16DAW17 | ETSHB16P30EG7 / EPRA16DBW17 | ETSHB16P50EG7 / EPRA16DAW17 | ETSHB16P50EG7 / EPRA16DBW17 | ETSHB16P30EF7 / EPRA18DAW17 | ETSHB16P50EF7 / EPRA18DAW17 | ETSHB16P30EF7 / EPRA18DBW17 | ETSHB16P50EF7 / EPRA18DBW17 | ETSHB16P30EG7 / EPRA18DAW17 | ETSHB16P30EG7 / EPRA18DBW17 | ETSHB16P50EG7 / EPRA18DAW17 | ETSHB16P50EG7 / EPRA18DBW17 | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Puissance calorifique | Puissance calorifique-=-Min.-=-kW | kW | 3.70 | 3.70 | 3.70 | 3.70 | 3.70 | 3.70 | 3.70 | 3.70 | 3.96 | 3.96 | 3.96 | 3.96 | 3.96 (1) | 3.96 (1) | 3.96 (1) | 3.96 (1) | 4.40 | 4.40 | 4.40 | 4.40 | 4.40 | 4.40 | 4.40 | 4.40 | ||
| Nom. | kW | 5.90 | 5.90 | 5.90 | 5.90 | 5.90 (2) | 5.90 (2) | 5.90 (2) | 5.90 (2) | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 (2) | 9.00 (2) | 9.00 (2) | 9.00 (2) | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 (2) | 9.00 (2) | 9.00 (2) | 9.00 (2) | |||
| Max. | kW | 9.75 | 9.75 | 9.75 | 9.75 | 9.75 (1) | 9.75 (1) | 9.75 (1) | 9.75 (1) | 10.44 | 10.44 | 10.44 | 10.44 | 10.44 (1) | 10.44 (1) | 10.44 (1) | 10.44 (1) | 11.60 | 11.60 | 11.60 | 11.60 | 11.60 (1) | 11.60 (1) | 11.60 (1) | 11.60 (1) | |||
| Puissance absorbée | Chauffage | Min. | kW | 0.84 | 0.84 | 0.84 | 0.84 | 0.84 (5) | 0.84 (5) | 0.84 (5) | 0.84 (5) | 0.90 | 0.90 | 0.90 | 0.90 | 0.90 (5) | 0.90 (5) | 0.90 (5) | 0.90 (5) | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 (5) | 1.00 (5) | 1.00 (5) | 1.00 (5) | |
| Nom. | kW | 1.23 | 1.23 | 1.23 | 1.23 | 1.23 (2) | 1.23 (2) | 1.23 (2) | 1.23 (2) | 1.80 | 1.80 | 1.80 | 1.80 | 1.80 (2) | 1.80 (2) | 1.80 (2) | 1.80 (2) | 1.80 | 1.80 | 1.80 | 1.80 | 1.80 (2) | 1.80 (2) | 1.80 (2) | 1.80 (2) | |||
| Max. | kW | 2.17 | 2.17 | 2.17 | 2.17 | 2.17 (5) | 2.17 (5) | 2.17 (5) | 2.17 (5) | 2.32 | 2.32 | 2.32 | 2.32 | 2.32 (5) | 2.32 (5) | 2.32 (5) | 2.32 (5) | 2.58 | 2.58 | 2.58 | 2.58 | 2.58 (5) | 2.58 (5) | 2.58 (5) | 2.58 (5) | |||
| COP | 4.79 | 4.79 | 4.79 | 4.79 | 4.79 (2) | 4.79 (2) | 4.79 (2) | 4.79 (2) | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 (2) | 5.00 (2) | 5.00 (2) | 5.00 (2) | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 (2) | 5.00 (2) | 5.00 (2) | 5.00 (2) | ||||
| Chauffage d'eau chaude sanitaire | Général | Profil de charge déclaré | L | XL | L | XL | L | L | XL | XL | XL | L | L | XL | L | L | XL | XL | L | XL | L | XL | L | L | XL | XL | ||
| Climat moyen | Classe | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Chauffage des locaux | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C-=-Général | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C-=-Général-=-SCOP | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | |||||||||||||
| Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C-=-Général-=-Classe d'effic. saisonnière du chauffage d'ambiance | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | ||||||||||||||||
| Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C-=-Général | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C-=-Général-=-SCOP | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | ||||||||||||||
| Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C-=-Général-=-Classe d'effic. saisonnière du chauffage d'ambiance | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||||||||||||||
| Remarques | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | (1) - Puissance conformément à la norme EN14511 et valable pour la plage d’eau chauffée dT = 3~8°C à Ta 7°C | ||||
| (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (2) - Condition : Ta DS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | |||||
| (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | (3) - La puissance absorbée est la puissance totale des unités intérieures et extérieures, y compris la pompe de circulation ; conformément à la norme EN14511 | |||||
| Chauffage des locaux | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C-=-Général | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C-=-Général-=-SCOP | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | 3.57 | |||||||||||||
| Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 55 °C-=-Général-=-Classe d'effic. saisonnière du chauffage d'ambiance | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ | ||||||||||||||||
| Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C-=-Général | Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C-=-Général-=-SCOP | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | 4.71 | ||||||||||||||
| Chauffage des locaux-=-Sortie d'eau sous climat tempéré : 35 °C-=-Général-=-Classe d'effic. saisonnière du chauffage d'ambiance | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||||||||||||||